Essential Requirements for VHF UHF Radio System Equipment (ER No. TEC58432606)

Affects: Certification Process Safety Spectrum Management Testing BLE NFC PMR WLAN 13.56 MHz 2.4 GHz 5.1 GHz (U-NII-1) 5.2 GHz (U-NII-2a) 5.4 GHz (U-NII-2c) 5.8 GHz (U-NII-3) UHF (400-470 MHz) VHF (136-174 MHz)

Last Updated

18-NOV-26

VHF/UHF Radio System Equipment – Summary of Essential Requirements

1\. DOCUMENT DETAILS

The Essential Requirements (ER) for VHF/UHF Radio System Equipment have been issued by the Telecommunication Engineering Centre (TEC), Government of India, under the MTCTE framework.

ER Number: TEC58432606\
Year: 2026\
Certification Scheme: GCS\
Product Fee Group: C

The annexures referenced in this ER are based on “Annexures to ERs” No. TEC/SD/DD/TCP-222/02/June19, including subsequent updates published on the MTCTE portal.

2\. SCOPE AND PRODUCT VARIANTS

This ER covers VHF/UHF radio communication equipment, including base stations, fixed stations, handheld devices, mobile stations and repeaters.

The equipment is divided into seven variants:

Variant 1: VHF/UHF Baseband Equipment without Radio\
Variant 2: VHF/UHF Base Station – Baseband plus Radio\
Variant 3: VHF/UHF Base Station – Radio Only\
Variant 4: VHF/UHF Fixed Station\
Variant 5: VHF/UHF Handheld Portable Stations\
Variant 6: VHF/UHF Mobile Stations\
Variant 7: VHF/UHF Repeater

The testing requirements depend on the equipment variant and the interfaces supported by the product.

3\. TECHNICAL REQUIREMENTS

A. Safety Requirements

Equipment Safety:

All seven variants must comply with IS 13252-1, IEC 62368-1 or IS/IEC 62368-1, as specified in Annex-A1.

Battery Safety:

Battery safety requirements apply only to Variants 5 and 6 (handheld portable and mobile stations). The applicable standards are IS 16046 or EN/IEC 62133, as specified in Annex-A2.

B. EMI/EMC Requirements

The equipment must meet the applicable emission and immunity requirements specified in Annex-B.

Conducted and Radiated Emissions:

Compliance is required with CISPR 32 / EN 55032 under the TEC EMI/EMC standard.

Class A: Variants 1, 2, 3 and 7\
Class B: Variants 4, 5 and 6

Immunity Requirements:

The following tests are applicable:

- Electrostatic Discharge (ESD): EN/IEC 61000-4-2 – All variants
- Radiated RF Immunity: EN/IEC 61000-4-3 – All variants
- AC Voltage Dips and Short Interruptions: EN/IEC 61000-4-11 – Variants 1, 2, 3, 4, 6 and 7
- DC Voltage Dips and Short Interruptions: EN/IEC 61000-4-29 – Variants 1, 2, 3, 4, 6 and 7
- Electrical Fast Transients/Burst: EN/IEC 61000-4-4 – Variants 1, 2, 3, 4, 6 and 7
- Surge Immunity: EN/IEC 61000-4-5 – Variants 1, 2, 3, 4, 6 and 7
- Conducted RF Immunity: EN/IEC 61000-4-6 – Variants 1, 2, 3, 4, 6 and 7

C. VHF/UHF Radio Requirements

Radio testing applies to Variants 2, 3, 4, 5, 6 and 7. Variant 1 is excluded as it consists of baseband equipment without a radio.

The main requirements are:

- Radio Conformance: ETSI EN 300xxx / EN 301xxx, FCC CFR 47 Part 90 or ANSI/TIA-102.CAAA-E (Annex-C3).
- Operating Frequency: Must comply with the National Frequency Allocation Plan (NFAP), as specified in Annex-C1.
- Maximum Transmit Power: Must remain within the limits specified in the applicable DoT/WPC licence conditions (Annex-C2).

4\. INTERFACE REQUIREMENTS

The interface testing requirements vary depending on the product variant.

Variants 1 and 2 cover all listed interfaces, including Ethernet, E1, STM, Bluetooth Low Energy, NFC and WiFi.

Variants 4, 5 and 6 have requirements for BLE, NFC and WiFi. No additional interface requirements are listed for Variants 3 and 7.

A. Ethernet Interfaces – Variants 1 and 2

Optical Ethernet (Annex-H):

The following optical Ethernet interfaces are covered:

- 100G Optical Ethernet: IEEE 802.3ba, Clauses 86 and 88
- 40G Optical Ethernet: IEEE 802.3ba, Clauses 86 and 87
- 10G Optical Ethernet: IEEE 802.3ae, Clause 52
- 1G Optical Ethernet: IEEE 802.3z, Clause 38

Testing includes average launch power, receiver sensitivity and operating wavelength.

Electrical Ethernet (Annex-H):

Fast Ethernet (FE) and Gigabit Ethernet (GE) electrical interfaces are tested for link speed and autonegotiation in accordance with IEEE 802.3.

B. 2 Mbps E1 Interface – Variants 1 and 2

The E1 interface requirements are covered under Annex-I.

The applicable parameters include:

- Input jitter tolerance and output jitter: ITU-T G.823 / ETSI TBR-4
- Input return loss: ITU-T G.703 / ETSI TBR-4, Clause 9.3.1
- Nominal bit rate and tolerance: ITU-T G.703 / ETSI TBR-4, Clause 9.2.3
- Pulse mask: ITU-T G.703 / ETSI TBR-4, Clause 9.2.1

C. STM Interfaces – Variants 1 and 2

STM interface requirements are specified in Annex-K.

STM-1 Electrical Interface:

- Input jitter tolerance and output jitter: ITU-T G.825
- Input return loss, nominal bit rate with tolerance and pulse mask: ITU-T G.703

STM-1, STM-4 and STM-16 Optical Interfaces:

- Input jitter tolerance: ITU-T G.825
- Output jitter: ITU-T G.783
- Mean launched power, nominal bit rate with tolerance, operating wavelength range, receiver overload and receiver sensitivity: ITU-T G.957

STM-64 Optical Interface:

- Input jitter tolerance: ITU-T G.825
- Output jitter: ITU-T G.783
- Nominal bit rate with tolerance: ITU-T G.707
- Mean launched power, operating wavelength range, receiver overload and receiver sensitivity: ITU-T G.691

D. Wireless Interfaces – Variants 1, 2, 4, 5 and 6

The ER also includes requirements for Bluetooth Low Energy (BLE), Near Field Communication (NFC) and WiFi.

Bluetooth Low Energy (BLE):

- EIRP: WPC GSR 45(E), Annex-G4 (4.2)
- Operating frequency: Latest NFAP, Annex-G4 (4.1)
- Spurious emissions: Annex-G3

Near Field Communication (NFC):

- Operating frequency: Latest NFAP, Annex-G6 (6.1)
- Spurious emissions: Annex-G3

WiFi:

For 2.4 GHz WiFi, radio conformance must be demonstrated against ETSI EN 300 328, FCC CFR 47 Part 15.247 or FCC CFR 47 Part 15.249.

For 5 GHz WiFi, the applicable standards are ETSI EN 301 893 and/or ETSI EN 302 502, or FCC CFR 47 Part 15.407 or Part 15.249.

Additional requirements include:

- EIRP: As per the latest NFAP and applicable GSR notifications issued by DoT/WPC (Annex-G2).
- Operating Frequency: As per DoT/WPC GSR Nos. 45(E) and 1048(E) (Annex-G1).
- Radio Conformance: As specified in Annex-G3.

5\. SUMMARY

The VHF/UHF Radio System Equipment ER outlines the safety, EMI/EMC, radio and interface testing requirements for seven equipment variants under MTCTE.

Safety and basic EMI/EMC requirements apply to all variants, while radio and interface testing requirements depend on the equipment configuration.

For certification, the product variant needs to be identified first, followed by the applicable tests based on the supported radio functions and interfaces.

The latest TEC annexures, NFAP provisions and DoT/WPC notifications should also be checked when determining the final testing and certification requirements.


Attached Documents & Source Files

Essential Requirements for VHF UHF Radio System Equipment (ER No. TEC58432606)

Author / Agency: Telecommunication Engineering Centre (TEC), Government of India

Published: 2026-06-01
Language: English

Key Regulatory Timeline & Dates

Jun 01, 2026
Date Published Published in 2026 under ER No. TEC58432606 (2606 indicates June 2026)

Stay Ahead of Global Regulatory Changes

Eleos Compliance delivers proactive regulatory monitoring, standard gap analysis, and type approval management across 150+ countries.